Breathe Easy Home Inspections

Executive Summary

9012 South Sample Ave, Mesa, AZ
Built 2001 Inspected November 7, 2026 Report 120 Inspector John Kirkwood
0
Safety items
0
Evaluate items
0
Maintenance items

AI-generated summary. It may contain errors or omit findings. The complete inspection report governs; full notices are below.

Bottom line

This 2001 Mesa home has several occupant-safety electrical items (exposed panel wiring, missing GFCI protection, no AFCI protection, missing CO alarms) and a garage door spring that has lost tension, all needing evaluation by a licensed electrician or garage door technician. Roof tile damage and cracked flashing mortar, moderate exterior flatwork cracking, and moisture staining at the garage and laundry shared wall and the laundry attic gable wall warrant further contractor review to find the cause. The sewer line is functioning with grease and debris buildup, and maintenance items (aged water heater, aged windows, cosmetic cracking, worn fixtures) round out the report.

From your walkthroughThe items your inspector went over with you in person. Details are in the findings below and in the full report.

  1. Electrical panel has a disconnected wire with no wire nut. Licensed electrician needed.
  2. Kitchen counter outlets and other wet areas are missing GFCI protection.
  3. No carbon monoxide alarms where they're required, and the smoke alarms are past their service life.
  4. Garage door spring has lost tension and the door drops on its own. Leave the spring to a garage door tech.
  5. Range has no anti-tip bracket.
  6. Water heater is a 2006 unit, past its typical service life, with no expansion tank.
  7. Cracked and loose roof tiles. Have a roofer take a look.
  8. Moisture staining on the wall between the garage and laundry. A contractor should find the cause.
At a glance

Your house, system by system

4 with safety items · 6 to evaluate · 2 maintenance only. Safety items come first. Tap a system to see what the report lists.

Exterior & GroundsSafety5
  • Trip hazards at driveway, trench drain, and rear patioAn elevation change between masonry surfaces, a damaged decorative trench drain, and cracked/heaved rear patio surfaces each created trip hazards (9.2.4, 9.2.5, 9.5.2).
  • Negative grading sloping toward the foundationGrading at the east and front of the home sloped toward the structure rather than away, which can allow water to pond against the foundation during heavy rain (9.3.2, 9.3.4).
  • Leaning, out-of-plumb block privacy wallA block privacy wall was visibly leaning and out of plumb, suggesting movement in the wall or footing, though no imminent collapse risk was noted (9.7.3).
  • Moisture infiltration signs at privacy wall and garage/service doorsEfflorescence was present on the privacy wall, and moisture intrusion was observed at the garage door area and the garage service entry door (9.7.1, 14.2.5, 14.9.2).
  • Sliding door difficult to operate at rearThe rear sliding door was difficult to operate, which can indicate track wear, misalignment, or hardware deficiencies (8.9.2).
RecommendedRepairs by a qualified contractor are recommended for safety. Evaluation and correction by a qualified grading contractor is recommended. Evaluation by a qualified masonry contractor is recommended. Evaluation of the moisture sources by a qualified contractor is recommended. Repair by a qualified professional is recommended.
ElectricalSafety5
  • Disconnected conductor exposed in electrical panelA conductor in the electrical panel was found disconnected and without a wire nut or cap, creating an exposed, energized shock hazard (10.7.4).
  • No GFCI protection at kitchen counters and laundryGFCI protection was absent at kitchen countertop receptacles, required at construction, and at the laundry room receptacle (10.11.2, 10.11.3).
  • AFCI protection absent for bedrooms and living areasAFCI breakers, which detect arc faults and reduce fire risk, were not present for circuits serving bedrooms and living areas (10.10.2).
  • Water pipe bonding disconnected at panelThe bonding jumper connecting the water piping system to the electrical grounding system was found disconnected, increasing shock risk (10.9.6).
  • Unlabeled breaker found in off positionA circuit breaker in the disconnect was off and unlabeled, so the circuit it serves could not be identified (10.10.5).
RecommendedEvaluation by a licensed electrician is recommended. Evaluation and installation by a licensed electrician is recommended. Evaluation and repair by a licensed electrician is recommended. Evaluation by a licensed electrical contractor is recommended.
Appliances & LaundrySafety4
  • Range anti-tip bracket not installedAn anti-tip bracket was not installed or not functioning on the range, which can allow the appliance to tip forward if weight is placed on an open door (17.4.2).
  • Dishwasher missing high loop and anti-tip bracket findings separateThe dishwasher drain line lacked a proper high loop or air gap, which can allow wastewater to siphon back into the unit (17.3.2).
  • Microwave not functionalThe microwave did not power on when tested (17.5.2).
  • Refrigerator unplugged, condition unverifiedThe refrigerator was found unplugged at the time of inspection, so its operation could not be evaluated (17.6.3).
RecommendedInstallation by a qualified person is recommended for safety. Repair by a licensed plumber is recommended. Repair or replacement by a qualified person is recommended. Verification with the seller prior to closing is recommended.
GarageSafety2
  • Garage door spring lost tension, door drops unexpectedlyThe garage door spring lost tension and the door would not stay in place when partially opened, posing an injury risk (14.3.2).
  • Garage fire separation compromised by holes in drywallMultiple holes were observed in the garage ceiling and wall drywall, compromising the fire-rated separation from living space (14.6.5, 14.6.7, 14.6.8).
RecommendedEvaluation by a qualified garage door technician is recommended. Sealing and patching by a qualified person is recommended.
Other itemsSafety2
  • CO alarms missing at recommended locationsCarbon monoxide alarms were not present at all locations required for this home, which has gas appliances and an attached garage (10.17.2).
  • Smoke alarm removed and another aged past service lifeA smoke alarm was removed from a required location, and another present alarm appeared past its useful service life (10.16.3, 10.16.4).
RecommendedInstallation by a qualified person is recommended. Replacement and installation by a qualified professional is recommended.
PlumbingEvaluate4
  • Water pressure reading exceeds recommended maximumWater pressure tested at 80 to 90 psi despite a pressure-reducing valve being present, indicating the regulator is out of adjustment or failing (12.9.5).
  • Undersink moisture damage at kitchen cabinetMinor to moderate moisture damage was present on the cabinet floor beneath the kitchen sink, indicating past or present leakage (12.2.1).
  • Low hot water flow at primary bedroom tub faucetLow hot water flow was produced from the primary bedroom bathtub faucet (12.14.3).
  • Toilet anchor bolt and flush mechanism issuesA toilet handle had to be held down to flush fully, and another toilet's anchor bolts extended beyond the flange with a missing sanitary cap (12.17.2, 12.17.3).
RecommendedAdjustment or replacement by a licensed plumber is recommended. Repair by a qualified person and continued monitoring for leaks is recommended. Evaluation and repair by a licensed plumber is recommended. Repair by a licensed plumber is recommended.
RoofEvaluate2
  • Cracked, loose, and displaced concrete roof tilesCracked, broken, loose, and displaced concrete tiles were observed in several roof areas, along with loose ridge tiles and deteriorated underlayment, which can allow moisture penetration (5.11.2, 5.11.3, 5.11.5, 5.11.6).
  • Cracked or missing mortar at tile flashing, missing storm collarCracked or missing mortar was found at concrete tile flashing on the east side, and a storm collar was missing at the b-vent, both of which may allow moisture entry (5.5.3, 5.5.4).
RecommendedEvaluation and repair by a qualified roofing contractor is recommended. Repair by a qualified roofing contractor is recommended.
Structure & AtticEvaluate2
  • Moisture staining at shared garage/laundry wall and laundry attic gableMoisture staining was present on the interior wall shared between the garage and laundry, and on the gable wall in the laundry room attic (3.3.2, 3.4.2).
  • Sparse or missing wall and ceiling insulationThermal imaging revealed sparse or missing insulation in walls and ceilings at several locations, reducing energy efficiency (6.6.4).
RecommendedEvaluation of the moisture source and repairs by a qualified contractor is recommended. Evaluation and installation by a qualified insulation contractor is recommended.
Heating & CoolingEvaluate2
  • Missing sediment traps at furnace and water heater gas linesSediment traps were absent on the gas piping serving the furnace and the water heater, which help prevent debris from entering appliance controls (11.7.2, 13.3.2).
  • HVAC filter missing and inadequate exterior unit clearanceNo air filter was installed at the return, and the exterior condensing unit lacked adequate horizontal clearance from the structure (11.3.2, 11.5.9).
RecommendedInstallation by a licensed plumber or HVAC contractor is recommended. Evaluation and servicing by a qualified HVAC contractor is recommended.
InteriorEvaluate2
  • Window operation and seal issues in multiple roomsSeveral windows were difficult to operate due to age-related wear, and some showed possible seal failure indicated by haze or condensation between panes (15.3.4, 15.3.5, 15.3.6).
  • Kitchen cabinetry water staining from sink leakWater staining and related damage were present on kitchen cabinetry, including the sink base cabinet, related to the undersink moisture finding (15.2.3).
RecommendedEvaluation by a qualified window contractor is recommended. Repair after leak correction by a qualified person is recommended.
Water HeaterEvaluate1
  • Water heater at end of service life, missing drain pan and expansion tankThe 2006 water heater is at or beyond typical service life, and lacks a drain pan and expansion tank for the closed-loop system created by the PRV (13.1.2, 13.1.7, 13.5.2).
RecommendedEvaluation and servicing by a qualified plumbing contractor is recommended.
FoundationMaintenance–

Expansion joints, minor flatwork cracking

Sewer & DrainsMaintenance–

Grease and debris buildup, line functional

Routine maintenanceMaintenance9
  • Minor to moderate concrete cracking at flatwork, garage slab, and patioModerate settlement cracking was noted at the rear left flatwork, minor cracking at the garage slab, and minimal cracking at the patio; these are generally not structural but are recommended for sealing and monitoring (4.2.2, 4.6.2, 9.5.4).
  • Expansion joints bubbled at front flatworkExpansion joints between flatwork and foundation had buckled or deteriorated at the front of the home (7.2.2).
  • Sewer line grease and debris buildup, otherwise functionalA sewer camera scope found grease and scattered debris along roughly 70 feet of ABS and SDR pipe, with no breaks, root intrusion, or blockage, and satisfactory water flow.
  • Garage door, entry door, and cosmetic wear itemsLight visible around the garage door, a damaged panel, cosmetic damage to the garage entry door, a difficult-to-operate deadbolt, and cosmetic floor staining were noted (14.2.3, 14.2.4, 14.7.2, 14.7.3, 14.8.2).
  • Vegetation, drainage, and wall condition items at groundsVegetation contact with the structure, an abandoned/brown turf area, a loose cinder block pillar cap, and a gate difficult to operate were observed (9.4.1, 9.4.2, 9.6.1, 9.7.2).
  • Window screen, light fixture, and ceiling fan itemsA damaged window screen, non-functional light fixtures in the garage and primary bath, an unsecured exterior garage light fixture, and a wobbling ceiling fan with non-functional fan light were noted (8.3.2, 10.13.2, 10.13.3, 10.14.2, 10.14.3).
  • Interior cosmetic and operability items throughoutNail pops, an unworkmanlike flooring installation, doors not latching or missing guide tracks, missing door stops, heavy cabinet wear, and deteriorated window film were noted in various rooms (15.2.2, 15.3.7, 15.5.2, 15.5.3, 15.5.4, 15.7.5, 15.8.2).
  • Exterior wall gaps, condensate pan debris, and disposer noiseGaps/openings in the exterior wall assembly, loose/unsecured conduit, debris in the attic condensate drip pan, and an irregular noise from the garage disposal were noted (8.2.3, 10.2.3, 11.9.3, 17.2.2).
  • Minor plumbing and appliance itemsA gap between bathroom floor and tub, corrosion on a shut-off valve, missing anti-siphon spigot protection, a missing water softener (loop present, no unit installed), a missing dishwasher rinse-aid cap, and gunk buildup in the dishwasher were observed (12.3.2, 12.14.2, 12.18.2, 13.5.3, 17.3.3, 17.3.4).

Status reflects the inspector's findings, not a score. Red (Safety): conditions that affect occupant safety. Yellow (Evaluate): notable conditions where further evaluation by a licensed specialist is recommended. Green (Maintenance): routine upkeep typical for a home of this age.

Recommended specialist evaluationsConditions where the inspector recommends further evaluation by a licensed professional, in priority order.

1
Electrical panel and safety devices

A disconnected conductor without a wire nut, missing GFCI protection at kitchen counters and laundry, no AFCI breakers, and incomplete CO alarm coverage were found. Evaluation by a licensed electrician is recommended.

2
Roof covering and underlayment

Cracked, broken, loose, and displaced concrete tiles along with underlayment deterioration and missing storm collar were observed. Evaluation by a licensed roofing contractor is recommended.

3
Water heater age and safety components

The water heater is at or beyond its typical service life and lacks a drain pan and expansion tank. Evaluation by a licensed plumbing contractor is recommended.

4
Sewer line maintenance

The sewer scope found grease and debris buildup along the pipe walls, though flow was satisfactory and no breaks or root intrusion were seen. Cleaning by a licensed plumber is recommended.

Not evaluated in this inspection

radon testing, water softener/purification system function, window screen condition, low-voltage/smart-home wiring

About this summary

This page is a condensed, computer-generated summary of the full written inspection report. It does not include every finding, photo, or detail. Read the full report before making any decision about this property: it is the authoritative document, and if anything on this page differs from the full report, the full report governs. This inspection was performed in accordance with the applicable Standards of Practice and is subject to the terms, conditions, and limitations of the inspection agreement.

Online summary and chat expire . A PDF saved to your device remains available after the online link expires. Your original inspection report is separate.

Opens your browser’s print dialog. Choose Save as PDF (or a PDF printer) and check the preview before saving. Chat is not included.

Ask this report anythingAnswers about this report, plus general home education. Not a second inspection.

Answers are automatically generated for general information. They are not inspection findings, professional advice, or part of the inspection report. Refer to the full report and consult licensed professionals before acting on any condition. AI answers may contain errors or omit findings. Ask your inspector to clarify findings and limitations. Consult your real estate agent about purchase, negotiation, and BINSR decisions.

This page is a starting point, not the report. The full written report is the authoritative document.

John Kirkwood · BTR AZ 70422 · (480) 254-5708 · Breathe Easy Home Inspections
QR code to this report
Ask this report anything